Component specification
Important
This is a redundant component and the specification is provided for reference only.
A4.6: Whole Blood, Leucocyte Depleted
A unit of blood collected into an anticoagulant, containing less than 1×106 leucocytes.
A4.6.1: Technical information
- A unit of whole blood is collected in the UK from a suitable donor (see chapter 3 and chapter 5). The International Blood Pack specification contains 66.5 mL of anticoagulant and is suitable for the collection of 475 mL ±10%.
- Whole Blood, Leucocyte Depleted (LD) should be administered through a CE/UKCA/UKNI marked transfusion set.
A4.6.2: Labelling
For general guidelines, see chapter 6.6.
The following shall be included on the label:
(* = in eye-readable and UKBTS approved barcode format)
- Whole Blood, Leucocyte Depleted* and volume
- the blood component producer’s name*
- the donation number*
- the ABO group*
- the RhD group stated as positive or negative*
- the name, composition and volume of the anticoagulant solution
- the date of collection
- the expiry date*
- the temperature of storage
- the blood pack lot number.*
In addition, the following statements should be made:
INSTRUCTION
Always check patient/component compatibility/identity
Inspect pack and contents for signs of deterioration or damage
Risk of adverse reaction/infection, including vCJD
A4.6.3: Storage
For general guidelines, see chapter 6.7.
- The component may be stored for a maximum of 35 days at a core temperature of 4 ±2°C if an adenine‑supplemented anticoagulant is used, otherwise the maximum period of storage is 28 days at a core temperature of 4 ±2°C.
- Variation from the core temperature of 4 ±2°C must be kept to a minimum during storage and restricted to any short period necessary for examining, labelling or issuing the component.
- Exceptionally, i.e. due to equipment failure at a Blood Centre, red cell components which have been exposed to a core temperature not exceeding 10°C and not less than 1°C may be released for transfusion provided that:
- the component has been exposed to such a temperature change on one occasion only
- the duration of the temperature excursion has not exceeded 5 hours
- a documented system is available in each Blood Centre to cover such eventualities
- adequate records of the incident are compiled and retained
A4.6.4: Testing
In addition to the mandatory and other tests required for blood donations described in chapter 9, and leucocyte counting (see chapter 6.3 and chapter 7.1.1), a minimum of 75% of those components tested for the parameters shown in Table A4.6 shall meet the specified values.
Parameter | Specification | Frequency of test |
---|---|---|
Volume (1) | 475 mL ±10% |
1% or as determined by statistical process control (if ≤10 components produced per month then test every available component) |
Haemolysis | <0.8% of red cell mass |
As per chapter 7.1.3 |
Haemoglobin content | ≥40 g/unit |
1% or as determined by statistical process control (if ≤10 components produced per month then test every available component) |
Leucocyte count (2) | <1×106/unit |
As per chapter 6.3 and chapter 7.1.1 |
Notes on Table A4.6
- After volume losses resulting from leucodepletion.
- Methods validated for counting low numbers of leucocytes must be used.
A4.6.5: Transportation
For general guidelines, see chapter 6.11.
For red cell components, transit containers, packing materials and procedures should have been validated to ensure the component surface temperature can be maintained between 2°C and 10°C during transportation. Additionally:
- the validation exercise should be repeated periodically
- if melting ice is used, it should not come into direct contact with the components
- dead air space in packaging containers should be minimised
- as far as is practicable, transit containers should be equilibrated to their storage temperature prior to filling with components
- transport time normally should not exceed 12 hours
In some instances, it is necessary to issue red cell components that have not been cooled to their storage temperature prior to placing in the transit container. The transport temperature specified above is not applicable for such consignments.