Protocol 000005 – blood component fate information - Standards for electronic data interchange within the UK Blood Transfusion Services - Chapter 25
One data line structure is currently defined within this protocol. It is a multiple occurrence line with an entry for each item in the message (see Table 25.14). Please see explanatory notes below the table.
The data line has a line type indicator in common with the previous protocols to allow for additional line types to be created, if required.
It is expected that this message will be generated daily and will include information on all units that are:
- free for use
- allocated to a patient (either directly or notionally)
- marked as transfused or wasted in the period from the date the report was last gathered (minus 5 days) up until the present date
This message will be used for all products with the exception of certain batched products (such as anti-D). Some batched products are excluded as each dose may not be allocated a unique unit number (platelet pools are not excluded).
25.10.1: Data line
Field | Length | Description | Format | Mandatory? |
---|---|---|---|---|
1 | 5 | Line number | NNNNN | Yes |
2 | 1 | Line type | N | Yes |
3 | 15 | Unit number | C(15) | Yes |
4 | 9 | Product code | C(9) | Yes |
5 | 2 | Group ABO | C(2) | Yes |
6 | 1 | Group RhD | C(1) | Yes |
7 | 1 | Status | C(1) | Yes |
8 | 5 | Wasted classification code | C(5) | No |
9 | 8 | Date used/wasted | YYYYMMDD | No |
10 | 4 | Time used/wasted | HHMM | No |
11 | 3 | Patient age | NNN | No |
12 | 1 | Patient gender | C(1) | No |
13 | 10 | Blank field | C(10) | No |
14 | 2 | Checksum | NN | Yes |
15 | 1 | Terminator | Carriage return | Yes |
Notes on Table 25.14
- Line type (field 2)
-
The data line type is ‘1’
- Unit number (field 3)
-
ISBT 128 donation identification number (data characters with check character, e.g. ‘G151797123456L’)
- Product code (field 4)
-
This is the component code, and is either:
- a full 9-character Codabar code, including start and stop characters
- an 8-character ISBT 128 product code excluding the data identifier characters
- Group ABO (field 5)
-
‘A’ = group A
‘B’ = group B
‘O’ = group O
‘AB’ = group AB
- Group RhD (field 6)
-
‘+’ = RhD positive
‘–’ = RhD negative
- Status (field 7)
-
‘F’ = free
‘A’ = allocated
‘T’ = transfused
‘W’ = wasted
‘C’ = Confirmed transfusion
Note: confirmed transfusion refers to transfusions that have been positively confirmed by electronic means.
- Wasted classification code (field 8)
-
Only used if ‘Status’ (field 7) marked as wasted (‘W’).
The wasted classification codes are maintained by the Blood Stocks Management Scheme (see 25.10.2).
- Date used/wasted (field 9)
-
Only if marked as wasted (‘W’) or transfused (‘T’ or ‘C’).
Presumptive date should be included if exact date unknown.
- Time used/wasted (field 10)
-
Only if marked as wasted (‘W’) or transfused (‘T’ or ‘C’)
- Patient age (field 11)
-
Only if marked as transfused (‘T’ or ‘C’).
Age in number of full years.
- Patient gender (field 12)
-
Only if marked as transfused (‘T’ or ‘C’).
‘M’ = male
‘F’ = female
- Blank field (field 13)
-
This field is reserved for future use.
25.10.2: Wasted classification codes
The following codes are managed by the Blood Stocks Management Scheme (BSMS).
25.10.2.1: Red cells
- Code
-
TIMEX
- Full name
-
Time expiry
- Usage
-
The expiry date on the unit has passed
- Date in use
-
1 April 2001 to present
- Code
-
OTCOL
- Full name
-
Out of temperature control outside laboratory
- Usage
-
Unit has been left out of temperature range for longer than 30 minutes on the wards, in theatres or in any other non-laboratory location
- Date in use
-
1 April 2001 to present
- Code
-
OTCIL
- Full name
-
Out of temperature control inside laboratory
- Usage
-
Unit has been left out of temperature range for longer than 30 minutes in the laboratory
- Date in use
-
1 April 2001 to 31 March 2003
- Code
-
FFAIL
- Full name
-
Fridge failure
- Usage
-
The unit has been discarded as a direct result of a fridge failure
- Date in use
-
1 April 2003 to present
- Code
-
MISCN
- Full name
-
Miscellanous
- Usage
-
Any other reason the unit is wasted that is not covered by other codes
- Date in use
-
1 April 2001 to present
25.10.2.2: Platelets
- Code
-
MORNU
- Full name
-
Medically ordered not used
- Usage
-
Platelets ordered for medical procedure but not used
- Date in use
-
1 April 2003 to present
- Code
-
SORNU
- Full name
-
Surgically ordered not used
- Usage
-
Platelets ordered for surgical procedure but not used
- Date in use
-
1 April 2003 to present
- Code
-
STMEX
- Full name
-
Stock time expired
- Usage
-
If a stock of platelets is held, the expiry date on the unit has passed
- Date in use
-
1 April 2003 to present
- Code
-
WOSOL
- Full name
-
Wasted outside of laboratory
- Usage
-
Unit has been left out of temperature range for longer than 30 minutes outside the laboratory
- Date in use
-
1 April 2003 to present
- Code
-
WIMPT
- Full name
-
Wasted import
- Usage
-
Unit imported with patient but not used
- Date in use
-
1 April 2003 to present
- Code
-
MISCN
- Full name
-
Miscellanous
- Usage
-
Any other reason the unit is wasted that is not covered by other codes
- Date in use
-
1 April 2003 to present